An open riser is legal in a dwelling in the British document, on two conditions at once: the treads must overlap by at least 16 mm, and a 100 mm diameter sphere must not pass through the gaps. In buildings other than dwellings the same document refuses open risers outright.

Open riser: the conditions, and the sphere that tests them

checked 2026-09-16rots yes — the figures above move with the editionkept by The Nosing Line (a named line, not a person)

A section through an open-riser stair with the gap and the tread overlap dimensioned
The sphere is tested through the gap, not across the flight. Not to scale.
A comparison of the open-riser rule for dwellings and other buildings
The difference is the building type, not the stair.
A three-step flow for testing an open-riser flight
The sphere test is physical. It is not a calculation.

The two conditions are joined

The British document permits open risers in a dwelling only where both conditions are met. The overlap condition is about the geometry of the step: at least 16 mm of tread overlap, which is what makes the going measurable nosing to nosing. The sphere condition is about the opening: a 100 mm diameter sphere must not pass through. Meeting one and not the other is not a partial pass.

For buildings other than dwellings, the same document takes the opposite line and says to use risers that are not open. The stated reason is specific and worth quoting in full: it removes the possibility of the front of a foot or a walking aid being caught underneath.

Building typeOpen riserCondition
Dwelling (UK)permittedoverlap ≥ 16 mm and 100 mm sphere blocked
Other than dwelling (UK)not usedfoot or walking aid could be caught
Ship stair (US workplace)required if shallowopen risers where tread depth < 9.5 in
Alternating tread (US workplace)required if shallowopen risers where tread depth < 9.5 in

Where the workplace rule requires the opposite

The American workplace rule requires open risers in two stair types, on the reasoning that a ship stair or an alternating tread stair is too steep for a closed riser to be useful. A ship stair is installed at a slope of 50 to 70 degrees with open risers and a vertical rise between tread surfaces of 6.5 to 12 inches. An alternating tread stair sits in the same slope band and must have open risers where the tread depth is less than 9.5 inches.

So the same feature is required in one document, permitted with conditions in another, and refused in a third depending on the building type. That is not a contradiction in the documents; it is a difference in what each one is protecting.

An open riser changes what the going means. On a closed stair the going is measured nosing to nosing across a solid riser face. On an open riser the measurement still runs nosing to nosing, but there is no riser to sight against, which is why an open-riser flight is one of the few places where the going is genuinely hard to measure on a finished stair. An open riser is not the same as a missing riser: the gap is a designed dimension with a printed limit.

Owned elsewhere

The tread and riser bands the gap is measured against are owned by the tread and riser page. The guard that stops a fall through the side of an open flight is owned by the guard page. This page owns the gap.

Documents checked

  1. 1eCFR :: 29 CFR 1910.23 -- Ladderssupports the ladder requirements that sit alongside the stairway rule for steep access
  2. 2NFPA 101 Code Development -- Life Safety Codesupports the life-safety framework that decides when a riser may be left open
  3. 3Expert Tips: Code Requirements and Resources for Wood Stair Framing (WoodWorks)supports the framing guidance for the open-riser stair cases that are built in timber

Each line points at one specific document, with its own title as the link text. No line is a home page and no line is a search result.

File this and go Close this page after you have tested the gap with the sphere. The overlap condition is separate and both are required.

checked by date edition used deviation logged